SILENT INSTALL AND UNINSTALL OF PATIENTWORKS

This post outlines a simple way to silently install PatientWorks. Silent install is a typical way PatientWorks customers deploy PaientWorks software to client PC's.

Remember (1) Remoting.config files need to be configured and deployed in addtion to the installion of client machines. (2) If the machine is a client machine do not install Data Services ("Server" feature).

Silent Install: "PatientWorks 3.5.1.1 Setup.exe" /s /v"/qn INSTALLDIR=\"c:\program files\patientworks" ISX_SERIALNUM=xxxxxxxxxxxxxxxx ADDLOCAL=Common,InputManager"

Silent uninstall: "PatientWorks 3.5 Setup.exe" /s /x /v"/qn"

Features List Parameters:
    Common – needed by most other features
    Designer – Form Designer
    WorkflowStudio – Workflow Studio
    InputManager – Input Manager
    PrintManager – Print Manager
    DataCapture – Patient Data Manager
    Server – Server components
    Administrator – Server Administrator
    ASP.NET – web apps
    UserManual – User manual
    Help - help

Save this as a batch file (*.bat)



Once this batch file runs it may leave some old files in the PatientWorks directory. It is best practice to add to the batch file a delete command to remove the PatientWorks program files install folder.